The Webac Vibrator GmbH supplies the complete series of the compressed air turbine vibrators when desired also with ATEX-Certification.
Mounting and Operating Instructions
GENERAL INFORMATION:
The Pneumatic Turbine Vibrators of type VT produce rotary vibrations with different
frequencies and oscillation width depending on the air pressure and mass. The
vibrators allow to be operated indoors as well as outdoors. However, they are
not suitable to be operated inside of liquids of any kind.
|
Admissible ambient temperature: |
from 0°C to maximum 70°C (in explosive areas maximum 40°C) |
|
Admissible operating media: |
clean and oil-free compressed air or nitrogen |
|
Admissible operating pressure: |
from minimum 2.0 bar ü (30 PSI) to maximum 6.0 bar ü (90 PSI) |
CAUTION: The maximum operating pressure of 6 bar ü (90 PSI) must not be exceeded.
When employing the enclosed silencer in its perfect mounting condition, i.e.
without any shaking or self-resonance of the construction, the vibrator generates
a noise level of a maximum 60 to 75 dBA.
MOUNTING AND COMMISSIONING:
Prior to mounting, the vibrator has to be checked for any obvious visible damages
resulting from transport and storing. The vibrator must be mounted fixedly and
resistant to vibrations to the prepared fastening holes. The mounting surface
must be levelled and clean. We recommend a welded-on U-shaped profile or a big-sized
base plate with strongly rounded edges to be used as a support. When using the
vibrator outdoors avoid rain water or any other liquids to flow into the vibrator
via the exhaust air opening. If required, an exhaust pipe with has to be installed
in downward direction.
For the fastening of the vibrator, use threaded bolts having a minimum tensile
strength quality 8.8. The fastening torque should not exceed or fall below the
following values:
|
VT 7 / 9 |
M 6 |
min. 6 Nm: max. 10 Nm |
|
VT 13 / 16 / 17 |
M 8 |
min. 15 Nm: max. 21 Nm |
|
VT 24 / 31 |
M 10 |
min. 30 Nm: max. 42 Nm |
Use appropriate screw retention rings like serrated lock washers, retainer rings,
etc.. With longitudinal bores, use additional washers. Additionally, you may also
employ screw-fastening adhesive of medium hardness (e.g. Loctite 270). With this,
observe the instruction of the manufacture.
CAUTION: Missing bolts may lead to tearing-off and falling-down of the unit.
The used compressed air must be clean and oil-free. We recommend to pre-connect
a 50 um air filter. The groove-type ball bearings have been lubricated for life
and do not require any additional lubrication. The inlet and outlet bores are
marked with arrows, with the inlet bore having a smaller opening than the outlet
bore. Please make sure that all connections between the hose nozzle are mounted
in accordance to the valid instructions. Observe the instructions of the hose
manufacturers.
CAUTION: detaching pressure hoses or hose nozzles may cause injuries on the eyes, etc.
Mount the enclosed silencer to the outlet opening. Being operated without silencer,
the vibrator causes an extreme noise load.
CAUTION: Any operation without silencer is not admitted. The outlet opening creates a
very loud noise when blowing out compressed air, which may cause injuries on the
ears and eyes.
COMPRESSED AIR SUPPLY:
In order to be able to operate the vibrators with full performance, make sure
to use an air compressor having a sufficient air and filter capacity and capable
of easily generating the required air quantities per minute as per the following
list:
|
VT 7 |
85 Ltr./min |
|
VT 9 |
105 Ltr./min |
|
VT 13 |
180 Ltr./min |
|
VT 16 |
225 Ltr./min |
|
VT 17 |
235 Ltr./min |
|
VT 24 |
325 Ltr./min |
|
VT 31 |
350 Ltr./min |
If the vibrator works very quickly on the constructive mass, it may be possible
that the output vibration energy is too weak. In this case, the result of the
vibration process is surely unsatisfactory and the wear of the unit is high. Here,
we recommend to employ a bigger vibrator in order to gain better results and to
conserve the unit.
CE Declaration of Conformity
OPERATION IN AN EXPLOSIVE ENVIRONMENT:
ATEX classification:
II 2G c T6
Operating conditions:
The Pneumatic Turbine Vibrators of the series VT are operative means of category
2 and allow to be employed in accordance to EN 1127-1, Annex B in Zone 1 and Zone
2 as well as with the gas groups II, which are endangered to cause explosions
in the areas of the temperature classes T1 to T5.
The admissible ambient temperature in Ex zones (explosive zones) is from 0°C
to +40°C.
Admissible operative media: clean and oil-free compressed air or nitrogen up
to a maximum of 6 bar and a maximum of 40°C.
Potential equalisation:
Make sure on mounting that the vibrator housing is electrically connected to
the system of potential equalisation of the installation!
Use:
The above-mentioned operating conditions must be strictly observed. In the case
the vibrator is employed in a way that its function may be of importance in view
to technical safety, the function must be strictly monitored.
|
CE DECLARATION OF CONFORMITY
With this, we declare in the scope of our own responsibility that the devices
indicated in the
following text are in full conformity with the regulations in the sense of Guideline
94/9/EG (ATEX).
Pneumatic Turbine Vibrators of the series VT
With the type denominations: VT 7 ; VT 9 ; VT 13 ; VT 16 ; VT 17 ; VT 24 ; VT
31
The technical documentation of the risk analysis is deposited at:
SEV Electrosuisse, Luppmenstrasse 1, CH-8320 Fehraltorf; code n° SEV 04 ATEX
0107
This declaration will lose its validity with constructional changes, with deviations
from the operating parameters indicated by the Operating Instructions, or with
any use of the devices which is not
in accordance with their original intended use.
Webac Vibrator GmbH
Wilhelmstraße 41
D-53879 Euskirchen
Herr Siegfried Anczikowski
Sales Management |
OPERATION AND MAINTENANCE:
Check the vibrator an hour after its first operation and one time per month to
ensure that all bolts, hose nozzle and silencers are still perfectly fixed.
In the case the vibrator works too slow, take off the silencer. If then the vibrator
works normal again, clean or replace the silencer. Proceed in the same way with
regard to the air filter.
CAUTION: when operating the vibrator without the silencer, wear an ear protection device.
Potential faults leading to a reduced performance:
| - |
The capacity of the compressor is too small, i.e. its output of litres/minute
is too small |
(replace) |
|
- |
The cross-section of the compressed air supply hose is too small or the hose
is too long
|
(replace or shorten)
|
|
- |
The silencer is strongly polluted |
(cleanse in paraffin oil or replace) |
|
- |
The groove-type ball bearings emit noise or do not run perfectly anymore
|
(replace) |
|
- |
Leaks in the piping |
(check the compressed air supply by means of leak indication spray)
|
|
- |
The air filter is strongly polluted |
(cleanse in paraffin oil or replace) |
|
- |
Sharp bents and/or squeezing of the compressed air hose
|
(replace or shorten)
|
Damaged devices must not be operated. With clearly indicating noises, replace
the ball bearings. Check the perfect functioning of the vibrator after 5.000 operating
hours at the latest. After 8.000 operating hours, replace the bearings and any
worn wear parts.
With repairs, only original spare parts of the manufacturer must be used! All
parts allow to be recycled. Store the Operating Instructions for any later employment. |